Development and evaluation of serotype-specific recombinase polymerase amplification combined with lateral flow dipstick assays for the diagnosis of foot-and-mouth disease virus serotype A, O and Asia1. BMC Vet Res. 2018 Nov 20;14(1):359-最新论文-保定市金诺兽药研究所

科研进展

当前位置: 首页» 科研进展» 最新论文

最新论文

Development and evaluation of serotype-specific recombinase polymerase amplification combined with lateral flow dipstick assays for the diagnosis of foot-and-mouth disease virus serotype A, O and Asia1. BMC Vet Res. 2018 Nov 20;14(1):359

Wang H , Hou P , Zhao G , Yu L , Gao YW , He H.

BMC Vet Res. 2018 Nov 20;14(1):359. doi: 10.1186/s12917-018-1644-4.

 
Abstract


BACKGROUND:

Foot-and-mouth disease (FMD) caused by foot-and-mouth disease virus (FMDV) is one of the most highly infectious diseases in livestock, and leads to huge economic losses. Early diagnosis and rapid differentiation of FMDV serotype is therefore integral to the prevention and control of FMD. In this study, a series of serotype-specific reverse transcription recombinase polymerase amplification assays combined with lateral flow dipstick (RPA-LFD) were establish to differentiate FMDV serotypes A, O or Asia 1, respectively.

RESULTS:

The serotype-specific primers and probes of RPA-LFD were designed to target conserved regions of the FMDV VP1 gene sequence, and three primer and probe sets of serotype-specific RPA-LFD were selected for amplification of FMDV serotypes A, O or Asia 1, respectively. Following incubation at 38 °C for 20 min, the RPA amplification products could be visualized by LFD. Analytical sensitivity of the RPA assay was then determined with ten-fold serial dilutions of RNA of VP1 gene and the recombinant vector respectively containing VP1 gene from FMDV serotypes A, O or Asia1, the detection limits of these assays were 3 copies of plasmid DNA or 50 copies of viral RNA per reaction. Moreover, the specificity of the assay was assessed, and there was no cross reactions with other viruses leading to bovine vesicular lesions. Furthermore, 126 clinical samples were respectively detected with RPA-LFD and real-time PCR (rPCR), there was 98.41% concordance between the two assays, and two samples were positive by RPA-LFD but negative in rPCR, these were confirmed as FMDV-positive through viral isolation in BHK-21 cells. It showed that RPA-LFD assay was more sensitive than the rPCR method in this study.

CONCLUSION:

The development of serotype-specific RPA-LFD assay provides a rapid, sensitive, and specific method for differentiation of FMDV serotype A, O or Asia1, respectively. It is possible that the serotype-specific RPA-LFD assay may be used as a integral protocol for field detection of FMDV.

KEYWORDS:

FMDV; Lateral flow dipstick; Recombinase polymerase amplification; Serotype-specific

 

 